Hi I am using mia to estimate contamination levels. It works for all of my samples but one, for which I get this error:
Making kmer list for k-mer filtering...
Starting to align sequences to the reference...
...
Repeat and score filtering
Repeat and score filtering
Generating new assembly consensus
Starting assembly iteration 2
Repeat and score filtering
mia: line 15: 23680 Segmentation fault mia -r rCRS.fa -f ${SAMPLE}.fastq -c -C -U -i -F -k 14 -m ${SAMPLE}.fastq.maln
When I disable iterations (-i flag replaced by -n) it works. I also tried different k values but I do not think that it is related to the issue.
Any thoughts? Can I trust the results without the iterations?